991 research outputs found

    Interferometric length metrology for the dimensional control of ultra-stable Ring Laser Gyroscopes

    Full text link
    We present the experimental test of a method for controlling the absolute length of the diagonals of square ring laser gyroscopes. The purpose is to actively stabilize the ring cavity geometry and to enhance the rotation sensor stability in order to reach the requirements for the detection of the relativistic Lense-Thirring effect with a ground-based array of optical gyroscopes. The test apparatus consists of two optical cavities 1.32 m in length, reproducing the features of the ring cavity diagonal resonators of large frame He-Ne ring laser gyroscopes. The proposed measurement technique is based on the use of a single diode laser, injection locked to a frequency stabilized He-Ne/Iodine frequency standard, and a single electro-optic modulator. The laser is modulated with a combination of three frequencies allowing to lock the two cavities to the same resonance frequency and, at the same time, to determine the cavity Free Spectral Range (FSR). We obtain a stable lock of the two cavities to the same optical frequency reference, providing a length stabilization at the level of 1 part in 101110^{11}, and the determination of the two FSRs with a relative precision of 0.2 ppm. This is equivalent to an error of 500 nm on the absolute length difference between the two cavities

    Lithuanian pension system’s reforms transformations and forecasts

    Get PDF
    The aim of this article is to describe the Lithuanian pension system, its reform process and its long-term financial sustainability. We define therefore the current reforms in the public pension system, influenced by the last economic crisis and social challenges. Also, we forecast the financial dynamics of the public pension system, in the light of raising social expenses (due to second pillar pension reforms) and of demographic trends (like ageing society and low fertility). Results reveal the long-term sustainability of the system, albeit at a cost of initial negative balances to be covered with public budget. Policy solutions could improve sustainability by encouraging and extending employment (especially for the disadvantaged) and by building trust in both public and private pension systems

    Rotational sensitivity of the "G-Pisa" gyrolaser

    Full text link
    G-Pisa is an experiment investigating the possibility to operate a high sensitivity laser gyroscope with area less than 1m21 \rm m^2 for improving the performances of the mirrors suspensions of the gravitational wave antenna Virgo. The experimental set-up consists in a He-Ne ring laser with a 4 mirrors square cavity. The laser is pumped by an RF discharge where the RF oscillator includes the laser plasma in order to reach a better stability. The contrast of the Sagnac fringes is typically above 50% and a stable regime has been reached with the laser operating both single mode or multimode. The effect of hydrogen contamination on the laser was also checked. A low-frequency sensitivity, below 1Hz1 \rm Hz, in the range of 10−8(rad/s)/Hz10^{-8} \rm {(rad / s)/ \sqrt{Hz}} has been measured.Comment: 6 pages, 6 figures, presented at the EFTF-IFCS joint conference 200

    Neuroinflammation and Neurodegeneration

    Get PDF
    Pathophysiological processes of neurodegenerative diseases are not clearly defined. However, an important body of evidence points toward the role of various inflammatory processes. The microglial cell is the main representative of the immune system in the central nervous system (CNS). This cell type can sense foreign or harmful pathogens and trigger its own activation and the generation of neuroinflammatory processes through phagocytosis and the release of cytokines, in order to maintain the cellular microenvironment. However, after maintaining a permanent state of activation due to sustained stimulation over time, microglial cells may generate a focus of persistent inflammation that in some cases precedes or enhances the neurodegenerative process. Thus, neuroinflammatory microenvironment becomes toxic and harmful for the neuronal cell, which degenerates and releases various factors that in turn activate the inflammatory response of microglia, potentiating the neurodegenerative cycle. In this chapter, we discuss the evidence on the role of microglial cell activation in neurodegenerative conditions and the association between neuroinflammatory processes and age-related neurological diseases. Finally, we outline how this new approach can help us to find new ways to understand neurodegenerative processes and to orientate the search for new therapies

    Lightning performance evaluation of Italian 150 kV sub-transmission lines

    Get PDF
    A significant majority of overhead transmission lines' (OHLs) outages is due to backflashovers caused by direct lightning strikes: the realistic assessment of the lightning performance is thus an important task. The paper presents the analysis of the lightning performance of an existing 150kVItalian OHL, namely, its backflashover rate (BFOR), carried out by means of anATP-EMTP-based Monte Carlo procedure. Among other features, the procedure makes use of a simplified pi-circuit for line towers' grounding system, allowing a very accurate reproduction of transient behaviours at a very low computational cost. Tower grounding design modifications, aimed at improving the OHL lightning performance, are also proposed and discussed

    Geometrical scale-factor stabilization of square cavity ring laser gyroscopes

    Get PDF
    Large frame ring laser gyros performances are ultimately limited by the instabilities of their geometrical parameters. We present the experimental activity on the GP2 ring laser gyro. GP2 is a ring laser gyro devoted to develop advanced stabilization techniques of the ring cavity geometrical scale-factor. A method based on optical interferometry has been developed for canceling the deformations of the resonator. The method is based on the measurement and stabilization of the absolute length of the cavity perimeter and of the resonators formed by the opposite cavity mirrors. The optical frequency reference in the experiment is an iodine-stabilized He-Ne laser, with a relative frequency stability of 10-11. The measurement of the absolute length of the two resonators has been demonstrated up to now on a test bench. We discuss the experimental results on GP2: the present performances as a ring laser gyro and the stabilization scheme to be implemented in the near future

    A high sensitivity tool for geophysical applications: A geometrically locked Ring Laser Gyroscope

    Full text link
    This work demonstrates that a middle size ring laser gyroscope (RLG) can be a very sensitive and robust instrument for rotational seismology, even if it operates in a quite noisy environment. The RLG has a square cavity, 1.60×1.601.60\times 1.60 m2^2, and it lies in a plane orthogonal to the Earth rotational axis. The Fabry-Perot optical cavities along the diagonals of the square were accessed and their lengths were locked to a reference laser. Through a quite simple locking circuit, we were able to keep the sensor fully operative for 14 days. The obtained long term stability is of the order of 3~nanorad/s and the short term sensitivity close is to 2~nanorad/s⋅\cdotHz−1/2^{-1/2}. These results are limited only by the noisy environment, our laboratory is located in a building downtown.Comment: 9 pages, 4 figures, 25 reference

    Length measurement and stabilization of the diagonals of a square area laser gyroscope

    Get PDF
    Large frame ring laser gyroscopes are top sensitivity inertial sensors able to measure absolute angular rotation rate below prad s-1 in few seconds. The GINGER project is aiming at directly measuring the Lense-Thirring effect with an 1% precision on an Earth based experiment. GINGER is based on an array of large frame ring laser gyroscopes. The mechanical design of this apparatus requires a micrometric precision in the construction and the geometry must be stabilized in order to keep constant the scale factor of the instrument. The proposed control is based on square cavities, and relies on the length stabilization of the two diagonals, which must be equal at micrometric level. GP2 is the prototype devoted to the scale factor control test. As a first step, the lengths of the diagonals of the ring cavity have been measured through an interferometric technique with a statistical accuracy of some tens of nanometers, and they have been locked to the wavelength of a reference optical standard. Continuous operation has been obtained over more than 12 h, without loss of sensitivity. GP2 is located in a laboratory with standard temperature stabilization, with residual fluctuations of the order of 1 C. Besides the demonstration of the control effectiveness, the analysis of the Sagnac frequency demonstrates that relative small and low-cost ring lasers (around one meter of side) can also achieve a sensitivity of the order of nrad s-1 in the range 0.01-10 Hz in a standard environment, which is the target sensitivity in many different applications, such as rotational seismology and next generation gravitational waves detectors
    • …
    corecore